核心提示:Acrel Rebecca(鮑靜君) Abstract: the necessity of applying residual current relay in intelligent building is analyzed, the

Acrel Rebecca(鮑靜君)

Abstract: the necessity of applying residual current relay in intelligent building is analyzed, the main functions, working principle, classification situation of ASJ residual current relay are introduced, and the principles and precautions in selecting residual current protection circuit breaker are indicated.

Keywords: ASJ residual current relay; intelligent building; application.

1. Background

The residual current relay is to detect the residual current and compare the residual current value with the reference value. When the residual current value exceeds the reference value, An electrical appliance that sends out a mechanical opening and closing signal. The residual current relay is usually composed of a combined residual current protection device with low voltage circuit breaker or low voltage contactor. It is mainly suitable for TT and TN system distribution lines with rated voltage of 50 Hz, and below. It can also provide indirect contact protection for personal electric shock, so it can be widely used in intelligent building power supply and distribution system.

2. Main uses of residual current relay

2.1  Protection of Indirect Contact Electric Shock

The measure of indirect contact electric shock protection is to automatically cut off the power supply. GB 13955" the protection of indirect contact electric shock accident "stipulates :" the main measure of indirect contact electric shock accident protection is to adopt the protection mode of automatically cutting off the power supply to prevent the damage accident caused by the insulation damage of electrical equipment. When the circuit insulation damage caused by grounding fault. When the fault current value is less than the operating current value of the over-current protection device, the residual current protection device shall be installed ." According to the research, the safe value of contact voltage is 50V. For personal safety, when insulation failure occurs in any part of the electrical device, once the contact voltage exceeds 50V, it is necessary to automatically cut off the fault part of the power supply within the specified time. The over-current protection device is limited by the electrical circuit and equipment and its own action value, and can not automatically cut off the power supply. The residual current protection device is not affected by the load current and can be used in conjunction with the over-current protection device for indirect contact electric shock protection.

2.2  Ground fault protection

Grounding is the contact between a live conductor and the earth, a grounded metal shell or a component connected to the ground. Its failure may lead to personal electric shock casualties and equipment damage, and may cause electrical fire in serious cases. Ground fault protection used to be protected by over-current protection device. When the grounding fault current is greater than the fixed value of the over-current protection device, the fault circuit is cut off by the over-current protection device.

In TT system, the line with larger rated current and longer distribution line, grounding fault of live conductor, unsafe metallic grounding fault and arc grounding fault in TN system may occur that the grounding fault current is less than the setting current of over-current protection action, and the over-current protection device does not act. Residual current protection device, or circuit breaker with ground fault protection, can reliably carry out ground fault protection.

2.3  Electrical fire protection

Electrical fire is usually caused by electrical short circuit, which includes metal short circuit and arc short circuit. The former is a short circuit between live conductors (such as between phases, between phases and N lines). The fault current is calculated in kilo ampere. High temperature is easy to cause insulation oxidation and spontaneous combustion.

Although the fire hazard is great, it can be protected by circuit breakers and fuses with short circuit protection, and the power supply is cut off by instantaneous action of circuit breaker to avoid fire. The latter is a live conductor short circuit to the ground, mostly arc as the path, although the fault current is small, but on the one hand, the arc lasts for a long time, the local temperature is high, it is easy to ignite the surrounding combustible material and cause fire. Therefore, the fire hazard caused by arc short circuit is much greater than that of metal short circuit. The circuit breaker with residual current action protection function can cut off the support circuit without the operation of the over-current protection device to prevent the electrical fire caused by the arc short circuit.

3. ASJ Series of Residual Current Relay

3.1 Model Function

3.2 Technical Parameters

3.3 Typical Application Schematic

4.Examples of application of residual current relay in intelligent building

4.1Intelligent residential buildings and hotel rooms

The electric iron, hair dryer and electric kettle in residential and hotel have high frequency of use, which are prone to wire breakage and water splashing to socket, which seriously endanger personal safety and need to monitor leakage current and protect it. The residual current relay is installed in the intelligent residential building and hotel room, which can cut off the power supply and protect the personal safety in the case of leakage or electric shock.

4.2 Swimming Pool in Intelligent Building

Modern sports fields and hotels are mostly intelligent buildings with swimming pool. In order to ensure the swimming pool is clean, the general swimming pool is equipped with circulating water pump system. Swimming pool is a crowded place. In order to ensure the safety of personnel, the circulating water pump system of swimming pool should be equipped with residual current relay. Ensure timely tripping, cutting off power supply and protecting personal safety when leakage fault occurs in circulating water pump system.

4.3 Intelligent construction site

Intelligent construction sites are commonly used to bulk cement and concrete mixers, tower cranes and other construction machinery, hand drills, cutting machines and other mobile power tools, need to supply them temporary power. The general construction site environment is wet, the personnel is numerous, the structure is complex, the electric equipment is mostly mobile, and the distribution line is long and complex, easy to be damaged by the external force, it is easy to cause the leakage and endanger the safety of personnel. Therefore, the residual current relay with rated residual current about 30mA should be set up in the construction site.

5.Summary

Acrel ASJ series of residual current relays have been applied in many occasions, such as industry, civil, subway, intelligent building and so on, which has played a good protective effect and is worth promotional use.

關(guān)注本網(wǎng)官方微信 隨時閱讀專業(yè)資訊

 
關(guān)鍵詞: the and current is of
 
打賞
[ 新聞資訊搜索 ]  [ 加入收藏 ]  [ 告訴好友 ]  [ 打印本文 ]  [ 違規(guī)舉報 ]  [ 關(guān)閉窗口 ]
免責(zé)聲明:
本網(wǎng)站部分內(nèi)容來源于合作媒體、企業(yè)機構(gòu)、網(wǎng)友提供和互聯(lián)網(wǎng)的公開資料等,僅供參考。本網(wǎng)站對站內(nèi)所有資訊的內(nèi)容、觀點保持中立,不對內(nèi)容的準確性、可靠性或完整性提供任何明示或暗示的保證。如果有侵權(quán)等問題,請及時聯(lián)系我們,我們將在收到通知后第一時間妥善處理該部分內(nèi)容。
 

Platform of Acrel Mars Leakage Relay in Intellvs91化學(xué)工業(yè)儀器網(wǎng)二維碼

掃掃二維碼用手機關(guān)注本條新聞報道也可關(guān)注本站官方微信賬號:"xxxxx",每日獲得互聯(lián)網(wǎng)最前沿資訊,熱點產(chǎn)品深度分析!
 

 
0相關(guān)評論

 
人人做人人妻人人精| 亚洲欧美日韩成人高清在线一区| 吃奶摸下高潮60分钟免费视频| 国产免费无码一区二区视频| 波多野结衣中文字幕久久| 刺激性视频黄页| 真实人与人性恔配视频| 日本无码人妻波多野结衣| 亚洲熟妇无码av另类vr影视| 日韩av片无码一区二区不卡| 亚洲精品国偷拍自产在线观看蜜桃 | 高潮潮喷奶水飞溅视频无码| 亚洲va在线∨a天堂va欧美va| 激情综合色五月丁香六月亚洲| 国产乱人伦精品一区二区| 一区二区乱子伦在线播放| 亚洲日韩精品a∨片无码| 亚洲精品无播放器在线播放| 国产成人无码aa精品一区| av片在线观看免费| 妺妺跟我一起洗澡没忍住 | 无码av天堂一区二区三区| 久久精品国产亚洲av瑜伽| 亚洲国产精品毛片av不卡在线| 成人永久免费网站在线观看| 久久精品中文无码资源站| 中文www新版资源在线 | 国产欧美精品区一区二区三区 | 4hu四虎永久免费地址ww416| 成年美女黄网站色大免费视频| 狠狠噜天天噜日日噜视频麻豆| 丰满老熟妇好大bbbbb| a级毛片无码免费真人久久| 国产色xx群视频射精| 人妻精品国产一区二区| 女人夜夜春高潮爽a∨片传媒| 全国最大成人网| 东北少妇不戴套对白第一次| 国产真人无遮挡作爱免费视频 | 日韩一区二区三区高清电影| 色窝窝亚洲av网在线观看|